Poly Aluminium Chloride MSD
[vc_row][vc_column][vc_column_text]MATERIAL IDENTIFICATION Technical Name    Poly Alluminium Chloride    Synonyms : PAC, Poly aluminum hydrochloride Chemical Formula :       (Aln (OH)m Cl 3n-m) Chemical Classification : Acid Hazard Class  8- Corrosive[/vc_column_text][vc_column_text]CAS Regi stry No : 1327-41-9           Haz Chern  Code    Hazardous Waste ID  UN No :  1760 Product  Use :  Used as a Coagulant for the treatment of drinking water.   Used as a sizing agent in Paper Industry [/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/4″][vc_column_text]HAZARDOUS INGREDIENTS Hazardous Ingredient :  LD50 Poly aluminium chloride[/vc_column_text][vc_column_text]PHYSICAL AND CHEMICAL PROPERTIES State  Clear Liquid Molecular weight Formula : (Aln (OH)m  Cl 3n-m) Containing 9.5 w/w/ Al2 o3  min 2.3 Vapour  pressure  : 30 mm Hg at 0°C Melting Point  : —[/vc_column_text][/vc_column][vc_column width=”1/4″][vc_column_text]Concentration : 10 %[/vc_column_text][vc_column_text]Colour Amber-light yellow Specific gravity : 1.2g/Cm3 at 20°C Vapour density : — Boiling Point : —[/vc_column_text][/vc_column][vc_column width=”1/4″][vc_column_text]CAS/UN NO :1327-41-9[/vc_column_text][vc_column_text]Odour Odourless Water  solubility :  Highly soluble miscible   pH     in all proportions. Freezing Point   :   10oC Others : —[/vc_column_text][/vc_column][vc_column width=”1/4″][vc_column_text]LC 50[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]FIRE / EXPLOSION HAZARD DATA Flammability Non Flammable Auto ignition temperature products Sensitivity to chemical impact  discharge[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_empty_space][vc_column_text]TOG Flammability Explosive range[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_empty_space][vc_column_text]Flash Point Hazardous combustion Sensitivity to static[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]REACTIVITY DATA Chemical Stability Stable at normal temperature and  pressure Reactivity products Reacts aggressively with some metal  surfaces (e.g.galvanised metal, aluminium   copper, zinc and  alloys of these metals) [/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]Dangerous reaction react with meal to liberate  flammable  hydrogen gas.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]HEALTH HAZARD DATA Route of entry Skin Contact. Ingestion,  inhalation. Effects on acute exposure Skin Contact:- May cause burns-  mild burns with 10% Eye Contact :-  May cause corneal damage Ingestion :- May cause damage to mucous, membranes,nausea. vomiting Sensitization to Material        : — PREVENTIVE MEASURES Storage requirement : Rubber lined tanks, plastic  tanks glass reinforced plastic tanks. Engineering Controls :Non Combustable  &  Corrosion resistant floor, dike  wall.[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]Permissible     limits TLV(c).2Mg/M3[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]Lethal dose Effects on Chronic exposure Synergistic materials : — Handling Methods: Pumping Personal protective equipment  Protective clothing, rubber gloves Eye goggles /  face shield, Gum boot.[/vc_column_text][/vc_column][vc_column][vc_column_text]Leak, spill handling: Do not allow run off to enter sewers or water ways small spills of liquid, absorb with sand large spills of liquid, contain then neutralise with caustic soda solution and dispose.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]Waste disposal Disposal of PAC using a licensed  waste disposal contractor EMERGENCY / FIRST- AID MEASURES Fire   extinguishment Not flammable Eyes &Skin : Ingestion[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]Special shipping information Special procedure Wash with running water atleast for 15 minutes , Do not induce vomiting, give small quantity of water to dilute the substance seek medical attention.[/vc_column_text][/vc_column][vc_column][vc_column_text]ADDITIONAL INFORMATION Poly aluminium chloride becomes unstable when stored or transported at temperature higher than 40oC[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]MANUFACTURER / SUPPLIER / CONSUMER DATA THE ANDHRA SUGARS LIMITED Chemicals & Fertilisers Division. KOVVUR-  534 350, A.P.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]Phones : 231597,231598,231599 Telex   :0474-242 Grams  : CHEMICALS Fax      :08813-231218[/vc_column_text][/vc_column][vc_column][vc_column_text]DISCLAIMER : The information contained in this Material Safety data sheet is believed to be reliable but no representation, guarantee or warranties of any kind are made as it’s accuracy, suitability for a particular application or results to be obtained from them. It is however, ensured that the information contained in the material safety data sheet is relevant to the product manufactured I handled or sold as the case may be by us.[/vc_column_text][/vc_column][/vc_row]