[vc_row][vc_column][vc_column_text]
MATERIAL IDENTIFICATION |
Technical Name : Hydrochloric Acid (36%) Synonyms : Muriatic Acid Hydrogen Chloride |
Chemical Formula : Hcl Chemical Classification : Inorganic Acid Hazard Class: Corrosive – 8 |
CAS Registry No.: 7647-01-0 | UN ‘No. :1789 | Haz Chem Code : 2R | Hazardous Waste 1D No.16 |
Product Use: Purifying Coke, Iron Ores, Packing Sheet Iron, Water Treatment, Photography, Pharmaceutical Industries. |
HAZARDOUS INGREDIENTS
Hazardous Ingredient : Chlorine, Hydrogen Concentration CAS/UN NO LC 50 LD50 |
PHYSICAL AND CHEMICAL PROPERTIES |
State Colour Odour |
Aqueous Solution Colourless Pungent |
Molecular weight: 36.47 Specific gravity: 1.19 at 20°C Water solubility : Dilutable pH-1 |
|
Vapour pressure : 280 mm Hg at 20°C Vapour density: 1.268 Freezing Point : -114.8°C |
|
Melting Point – —- Boiling Point : 110°C Others 442 Volumes of gas dissolves in one volume of water at 20°C |
FIRE I EXPLOSION HAZARD DATA
Flammability : Non Flammable TDG Flammability : —- Flash Point : —– |
Auto ignition temperature : — Explosive range : — Hazardous combustion products |
Toxic fumes of Hydrogen Chloride Chlorine |
Sensitivity to chemical impact : Stable Sensitivity to static discharge Stable |
|
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
REACTIVITY DATA
Chemical Stability : Stable[/vc_column_text][vc_column_text]
Reactivity
Violantly react with chemicals like
Ammonia, Ethylene; Oleum and bases.
Corrosive toimany metals Iron, Zinc.
Aluminium.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]Incompatibility
Common Metals Bases, Oxidisers, Oleum, Ethylene Carbides,[/vc_column_text][vc_column_text]
Dangerous reaction products
Hydrogen, Chlorine[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]
HEALTH HAZARD DATA
Route of entry:
Inhalation, ingestion, Skin contact
Effects on acute exposure
Severe irritation of respiratory tract,
Pulmonary edema, Corrosive to human tissue
And cause burns.
Sensitization to Material : Data not available[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_empty_space][vc_column_text]
Permissible limits
TLV{C)=5 ppm : 7 mg/M
3[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_empty_space][vc_column_text]
Lethal dose
LD50 (Rabbit) = 900mg/Kg[/vc_column_text][vc_column_text]
Effects on Chronic exposure
Dermititis, Teeth Damage, and Ulcers.[/vc_column_text][vc_column_text]Synergistic materials : Data not available[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
PREVENTIVE MEASURES
Storage requirement:
Bulk Storage : M.S.Rubber Lined Tanks.
Small quantities : Plastic Drums and Carboys.
Engineering Controls
Storage in ventilated Area
Acid resistant flooring
Dike walls
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Handling Methods
Pumping.[/vc_column_text][vc_column_text]
Personal protective equipment
Canister gas mask, protective clothing, hand gloves,
gum boot, face shield/ goggle.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]
Leak, spill handling
Contain leak preventing enter into public sewers, channels etc., wash out the leak or spill acid large amounts of water washings shall be neutralised before disposal spills can be covered with dry sand, burnt lime or washing soda.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
Waste disposal
Dilution with large amounts of water and
alkali matter to 7.0 pH before disposal[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Special shipping information
Grades of Purity : Technical 36% aqueous
Storage Temp. : Ambient
Inert Atmosphere : Not required
Venting : Open[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
EMERGENCY I FIRST – AID MEASURES
Fire extinguishment : Non flammable
First – Aid
Eyes/Skin Contact : Wash thoroughly with
copious amounts of running water.
Ingestion: Large intake water. Refer to physician soon.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Special procedure : —–
Antidotes[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
ADDITIONAL INFORMATION
MANUFACTURER I SUPPLIER I CONSUMER DATA
THE ANDHRA SUGARS LIMITED
Chemicals & Fertilisers Division.
KOVVUR – 534 350, A.P.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]KOVVUR:
Phones: 231597,231598,231599
Phone: 08811 – 253428
Grams : CHEMICALS
Fax:08813-231218[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]
DISCLAIMER.
The information contained in this Safety Data Sheet is believed to be reliable but no representation, guarantee or waranties of any kind are made as it’s accuracy, suitability for a particualr application or results to be obtained from them. It is however, ensured that the information contained in the material safety data sheet is relevant to the product manufactured / handled or sold as the case may be by us.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_separator style=”double”][vc_column_text]
HYDROCHLORIC ACID
MATERIAL IDENTIFICATION
Technical Name |
Hydrochloric Acid |
Synonyms |
Muriatic Acid Hydrogen Chloride |
Chemical Formula |
Hcl |
Chemical Classification |
Inorganic Acid |
|
|
Hazard Class : |
Corrosive – 8 |
CAS Registry No. |
7647-01-0 |
UN ‘No. |
1789 |
Haz Chem Code |
2R |
Hazardous Waste 1D No. |
16 |
Product Use: Used in purifying coke and iron ores, pickling sheet iron, Regeneration of water treatment resings, photography, pharmaceutical Industries
HAZARDOUS INGREDIENTS
Hazardous Ingredient
: Chlorine, Hydrogen Concentration :
CAS/UN NO LC 50 LD50[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]
PHYSICAL AND CHEMICAL PROPERTIES
State Aqueous Solution
Molecular weight 36.47
Vapour pressure 280 mm Hg at 20°C
Melting Point —-[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]
Colour Colourless
Specific gravity: 1.19 at 20°C
Vapour density: 1.268
Boiling Point 110°C[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]
Odour Pungent
Water solubility Dilutable
pH-
1
Freezing Point -114.8°C
Others —-[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]
FIRE I EXPLOSION HAZARD DATA
Flammability : Non Flammable
Auto ignition temperature : —
Sensitivity to chemical impact : Stable
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]
TDG Flammability : —-
Explosive range : —
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]
Flash Point : —–
Hazardous combustion products : —
Sensitivity to static discharge: Stable[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
REACTIVITY DATA
Chemical Stability : Stable
Reactivity
Violant reaction with bases, Ammonia, Ethylene; Oleum etc., Corrosive toimany metals like Iron. Zinc.Aluminium.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_empty_space][vc_column_text]
Incompatibility
Bases, Oxidisers, Oleum, Ethylene,Carbides, Common Metals Dangerous reaction products Chlorine, Hydrogen.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]
HEALTH HAZARD DATA
Route of entry
Skin contact, ingestion, Vapour Inhalation
Effects on acute exposure
Corrosive to human tissue, burns. Severe Irritation of respiratory tract, pulmonary edema.
Sensitization to Material : —-[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_empty_space][vc_column_text]
Permissible limits
TLV{C)=5 ppm : 7 mg/M
3[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_empty_space][vc_column_text]
Lethal dose
LD50 (Rabbit) = 900mg/Kg
Effects on Chronic exposure
Dermititis, Teeth Damage, Ulcers.
Synergistic materials : —–[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
PREVENTIVE MEASURES
Storage requirement:
Bulk Storage in M.S.Rubber Lined Tanks. Small quantities in Plastic Carboys.
Engineering Controls
Adequate ventilation. Acid resistant flooring Dike wall.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Handling Methods
Pumping through rubber lined or rigid PVC piping.
Personal protective equipment
Face shield, Hand Gloves, Gumboot, protective Clothing, Canister Gas Mask.[/vc_column_text][/vc_column][vc_column][vc_column_text]
Leak, spill handling
Contain leak, spill to preventing enter into sewers. Dilute spills with large amounts of water Neutralise washings with soda ash.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
Waste disposal
Neutralise with Alkaline matter before disposal.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Special shipping information
Grades of Purity : Technical 36% aqueous
Storage Temp. : Ambient
Inert Atmosphere : Not required
Venting : Open[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]
EMERGENCY I FIRST – AID MEASURES
Fire extinguishment : Non flammable
First – Aid
Eyes/Skin : Wash affected area with running. water atleast for 15 minutes.
Ingestion: Large intake of water.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text]
Special procedure : —–
Antidotes : —-[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]
MANUFACTURER I SUPPLIER I CONSUMER DATA
THE ANDHRA SUGARS LIMITED
Chemicals & Fertilisers Division
Saggonda – 534 318, A.P.
Kovvur
Phone: 08811 – 253428,231597,231598,231599
Grams : CHEMICALS
Fax:08813-231218
E.mail to: info.kvr@theandhrasugdars.com
DISCLAIMER.
The information contained in this Material Safety Data Sheet is believed to be reliable but no representation.Guarantee or werrenties of any kind are made as it’s accuracy, suitability for a particular application or results to be obtained”from them. It is however, ensured that the information contained in the material safety data sheet is relevant to the product manufactured / handled or sold as the case may be by us.
[/vc_column_text][/vc_column][/vc_row]