Liquid Chlorine Material Safety data
[vc_row][vc_column width=”1/2″][vc_column_text]MATERIAL IDENTIFICATION Technical Name :  Chlorine Chemical Formula :  Cl2 CAS Registry No.:7782-50-5 UN ‘No. :1017[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_empty_space][vc_column_text]Synonyms : Bertholite Chemical Classification : Inorganic Chemical Hazard Class: 2 & 6 Haz Chem Code : 2XE Hazardous Waste ID No.17[/vc_column_text][/vc_column][vc_column][vc_column_text]Product Use: Used in the Pulp & Paper, Textile Industries, Manufacture of Chemicals, Medicines,     Bleaching Powder, PVC etc., and disinfecting water.[/vc_column_text][vc_column_text]HAZARDOUS INGREDIENTS Hazardous Ingredient  :  Chlorine   Concentration       CAS/UN NO               LC 50             LD50[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]PHYSICAL AND CHEMICAL PROPERTIES State   Liquified Gas under pressure Molecular weight: 71 Vapour pressure : 6.3 atmp at 26°C Melting Point  –     —-[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]Colour GreenishYellow Gas Amber-Liquid Specific gravity: Liquid 1.468 at 0 °C          Vapour density: 2.482 at O°C Boiling Point : -34°C[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]Odour Pungent and Choking Odur Water solubility             Slightly soluble (Max 1% at 10°C) pH: — Freezing Point : -101 °C Others : Critical Pressure – 76.1 atm , Critical Temperature – 144°C [/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]FIRE I EXPLOSION HAZARD DATA Flammability  : Non Flammable Auto ignition temperature :  —       Sensitivity to chemical impact  : Stable[/vc_column_text][vc_column_text]REACTIVITY DATA Chemical Stability  : Stable Reactivity Mixture of Chlorine and Hydrogen is explosive.   Reacts with inorganic compounds such as lime, Caustic Soda, Soda ash and organic compounds such as hydro carbons, alchohols etc.[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]TDG Flammability :   —-       Explosive  range   :    LELof HYdrogen Chlorine mixture   3.1% to 8.1%[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]Flash Point : —– Hazardous combustion products : —- Sensitivity to static discharge Explosive in mixtures status with combustibles.[/vc_column_text][vc_column_text]Incompatibility Ammonia, Acetylene, Metals, Combustible materials Dangerous reaction products Trichloribensodoxin[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_column_text]HEALTH HAZARD DATA Route of entry: Inhalation, Skin contact, ingestion Effects on acute exposure Irritation of throat, intense cough, difficult in breathing. Pulmonary edema, Chest pain, vomtings, collapse, Freeze burns, imitation.   Sensitization to Material Data not available[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]Permissible limits TLV=1 PPM : 3 mg/M3 STEL=3 PPM : 9mg/M3[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_column_text]Lethal dose LC 50 (Rat) = 2933 PPM/1 Hour Effects on Chronic exposure Permanent loss in pulmonary function.Bronchitis, preposition to Tuberculosis.   Synergistic materials Data Not Available[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]PREVENTIVE MEASURES Storage requirement: Bulk Storage in Steel Tanks licenced under SMPV Rules Filled in steel tonners or cylinders  for shipment. Engineering Controls Adequate ventilation. Spare tank for emergency        transfer Dike wall, emergency scrubber etc. Leak, spill handling If the leak in piping, shut off the Chlorine supply. If the leak is from cylinders, position the cylinder so that leak will be in gaseous phase. Contain Liquid spills. Do not pour water on leak containers. Waste disposal Nuetralise the waste Chlorine or spills      with alkaline solutions such as Caustic  Soda, Soda ash or slaked lime etc. EMERGENCY I FIRST – AID MEASURES Fire extinguishment    Non flammable gas[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text] Handling Methods Seamless steel, seamless copper flxible piping are used for handling liquid Chlorine Personal protective equipment Self contained Breathing Apparatus Gas filters  Protective Clothing. Special shipping information Grades of Purity           :           Technical Storage Temp.             :           Ambient Inert Atmosphere        :           Not required Venting                          :           No vents Special procedure        :           —–[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]First – Aid                                                                                Antidotes  Remove the victim from contaminated area. Remove contaminated clothing. Provide fresh air circulation. Oxygen can be administered by trained person. If breathing ceased, start artifical respiration.[/vc_column_text][vc_column_text]ADDITIONAL INFORMATION One volume of liquid Chlorine expands 457 volumes of gas. Position the leak container so that leak spot comes at top, only gas escape  rather than liquid.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]MANUFACTURER I SUPPLIER I CONSUMER DATA THE ANDHRA SUGARS LIMITED Chemicals & Fertilisers Division. KOVVUR I SAGGONDA. Phone: 08811-253418; 253428 E.mail to: info.kvr@theandhrasugars.com[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_column_text] CONTACT ADDRESS: KOVVUR OFFICE: Phones: 231597,231598,231599 Grams : CHEMICALS Fax:08813-231218 [/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]DISCLAIMER. The information contained in this Material Safety Data Sheet is believed to be reliable but no representation, guarantee  or   waranties of any kind are made as it’s accuracy, suitability for a particualr application or results to be obtained from  them. It is however, ensured that the information contained in the material safety data sheet is relevant to the product manufactured I handled or sold as the case may be by us.[/vc_column_text][/vc_column][/vc_row]